Product Overview
GE Zoneline® Cooling and Electric Heat Unit with Makeup Air 12,000 BTU, 230/208 Volt
Makeup air - Delivers 25-50 CFM of continuous makeup air whenever the room is occupied
Quiet operation - Baked-on mastic sound barrier, cross flow blower and two DC fan motors create less noise to ensure comfort
Electronic touch controls with LED display - undefined
Simplified structure - Easy to maintain and service
Product built to order, lead times may vary
Energy efficiency - When paired with occupancy sensing hardware, ventilation can be halted during vacancy
Dehumidification - Dehumidifies at a rate of 5-6 pints per 24 hours (based on CFM level)
Indoor fan CFM (high/low) - 449/270
Heat & Freeze Sentinels - Keeps the room from overheating or freezing
Electronic temperature limiting - Prevents expensive over-cooling or over-heating of the room
SMC base pan
May reduce the need for individually ducted rooftop systems
Because makeup air increases room BTU load requirements and requires additional PTAC cooling or heating, the building’s electrical needs may be impacted
Makeup air models are not recommended for installation within two miles of coastal areas
It is strongly recommended to install makeup air with wall thermostats
Product Overview
GE Zoneline® Cooling and Electric Heat Unit with Makeup Air 12,000 BTU, 230/208 Volt
Makeup air - Delivers 25-50 CFM of continuous makeup air whenever the room is occupied
Quiet operation - Baked-on mastic sound barrier, cross flow blower and two DC fan motors create less noise to ensure comfort
Electronic touch controls with LED display - undefined
Simplified structure - Easy to maintain and service
Product built to order, lead times may vary
Energy efficiency - When paired with occupancy sensing hardware, ventilation can be halted during vacancy
Dehumidification - Dehumidifies at a rate of 5-6 pints per 24 hours (based on CFM level)
Indoor fan CFM (high/low) - 449/270
Heat & Freeze Sentinels - Keeps the room from overheating or freezing
Electronic temperature limiting - Prevents expensive over-cooling or over-heating of the room
SMC base pan
May reduce the need for individually ducted rooftop systems
Because makeup air increases room BTU load requirements and requires additional PTAC cooling or heating, the building’s electrical needs may be impacted
Makeup air models are not recommended for installation within two miles of coastal areas
It is strongly recommended to install makeup air with wall thermostats
custom.product.features
CAPACITY
CFM Indoor Fan High | 449 |
CFM Indoor Fan Low | 270 |
Cooling BTUH (MAX) | 11,700 Btu |
Cooling BTUH (MIN) | 11,500 Btu |
Cooling EER (BTUH / Watt) | 11.7/11.7 |
Dehumidification (pts./hr.) | 3.9 |
Vent CFM (high fan at zero ESP) | 25-50 |
FEATURES
Chassis Type | Slide-In |
Control Type | Coverless Backlit White LED Touch Controls |
Discharge Grille | 2-position |
Electronic Micro Computer Control | Yes |
Fan Cycle Switch | Yes |
Fan Motor | 2 |
Fan Speed Control | Yes |
Fan Speed Selections | Hi/Low Cooling Hi/Low Heating Hi/Low Fan Only |
Filter Type | Rigid Frame Slide-Out |
Heat - Cool | Yes |
Heating System | Electric Resistance |
Louver Style | Reversible |
Makeup Air | Yes |
Power Factor | 98 |
Product Type | Packaged Terminal Air Conditioners (PTAC) |
Refrigerant Type | R410A |
Rotary Compressor | Yes |
Sensible Heat Ratio | 66% |
Temperature Limiting | Electronic 7-Step |
Temperature Range | 60 - 85 F |
Zoneline Features | "Smart Fan" Fan Cycle Control Random Twist/Length Segment Tangential Blower Weather Protected Electrical Components "Sleep" Mode Heat Sentinel Freeze Sentinel Automatic Indoor Frost Control Universal Heaters Auto Power Recovery Remote Thermostat Compatibility Central Desk Control Compatibility Proportional - Integral ID Airflow |